Bambu Lab A1 Common Issues
Issue 1: Too low Z Offset / Wrong Temp for PETG
Problem with Z Offset + Temperature + Max Volumetric speed
Filament: PETG
Printing Speed Mode: Luminous
Z Offset: 0.06 / or could decrease by 0.05 if you want to test best fit for more filament
Temp: 265
Max Volumetric Speed: 12 mm3/s
;===== for Textured PEI Plate , lower the nozzle as the nozzle was touching topmost of the texture when homing ==
;curr_bed_type={curr_bed_type}
{if curr_bed_type=="Textured PEI Plate"}
G29.1 Z{0.06} ; for Textured PEI Plate
{endif}
Result: Good Print Surface
PLA
Z offset: 0.03
Calibration: Calibrate Your Filament Before Usage
Learn here
Change the K Value to : 0.03 and the value step: 0.001
Pick the best line which has good k factor for the printer
Same thing with the flow calibration:
Adjust your flow ratio in the project filament and save it.